Process Calibrator PCE-MCA 50

Views: 2051

$0.00

SKU: 6d7b886eaed5 Category:

Description

Process calibrator PCE-MCA 50
Universal calibrator with powerful battery /
Transducer for simulation and measurement / Generation of increments / Extensive measurement and simulation functions

The process calibrator PCE-MCA 50 is designed for calibration and maintenance. This process calibrator enables the measurement and simulation of electrical quantities. Due to the battery operation, the process calibrator PCE-MCA 50 can be used in different locations. The measurement functions offered are a versatile measuring instrument that can be used in many areas. Depending on the application, the process calibrator can run for up to 17 hours per battery charge. The measured results can be stored on the internal measured value memory. This offers a capacity for up to 15000 values.

The process calibrator offers the possibility of generating and measuring DC and DC. The operation of the process calibrator is carried out in a simple manner via nine keys installed on the front. Likewise, test leads and thermocouple can be connected. The process calibrator performs measurement functions, voltage and current simulations, as well as a continuity test. The measured values ​​can be read off the large LC display.

– Compact handset
– User friendly menu
– Rechargeable strong battery
– Adjustable backlight
– Extreme value and average measurement
– Continuity test
– USB interface
– ABS housing with rubber protective cover





Specification

   
Display modes Measurement: mA / V / mV / mA (24V) / Switch test / Temperature thermocouple / Resistance thermometer / Frequency / Pulse
  Simulation: mA / V / mV / mA (2 W) / Resistance / Resistance Thermometer / Temperature Thermocouple / Frequency / Pulse
Maximum input voltage 30V DC
Input impedance Measurement Thermocouple, mV, V, frequency, pulse: 1 MΩ

mA: 10 MΩ

Response time <100 ms
Load impedance > 4.7 KΩ for thermocouple / mV / V / pulse / frequency

<750 Ω for mA
Refresh rate display 10 readings per second
Isolation 500V DC
Data storage 150000 measured values ​​maximum
Interface USB 2.0
Display 3.2″ TFT LCD

240 x 320 pixels


LED illuminated
Output voltage Current loop 24V DC / 24-mA
HART mA loop Resistance 250 Ω ± 20%
Special features Step and ramp function

Automatic and manual


mode √x, x2: For the measuring function
Continuity test Adjustable threshold value up to 100 Ω
Power supply Rechargeable battery, 3000-mAh 3.7V
Charging time Max. 5 hours
Power adapter 100 … 240V AC, 50/60 Hz, output 5V DC at 1 A
Battery life > 17 h: Simulation and measurement with low LCD illumination

> 9 h: Measurement with low LCD illumination
Dimensions (L x W x H) 185.6 x 97.1 x 41.3 mm / 7.3 x 3.8 x 1.6 in
Weight <500 g / 1.1 lbs
Protection class IP20
Operating conditions 0 … 55°C / 32 … 131°F, 30 … 90% RH (non-condensing)
storage conditions -20 … 60°C / -4 … 140°F, 30 … 90% rh (non-condensing)
Heating time 5 minutes
   
Technical data electrical measurement
       
Parameter Measuring range Resolution Measurement accuracy
V 0 … 30V DC 0.001V ± 0.02% of v. Mw. ± 2 Dgt
mA 0 … 24-mA 0.001-mA ± 0.02% of v. Mw. ± 2 Dgt
       
Technical data electrical simulation
       
Parameter Measuring range Resolution Measurement accuracy
V 0 … 12V DC 0.001V ± 0.02% of v. Mw. ± 2 Dgt
mA 0 … 24-mA 0.001-mA ± 0.02% of v. Mw. ± 2 Dgt
       
Technical Data Measurement / Simulation Thermocouple mV
       
Type thermocouple Measuring range Resolution Measurement accuracy
       
e -200 … 1000°C /   -328 … 1832°F 0.1°C / 0.18°F ± 0.3°C / 0.54°F
J -200 … 1200°C /   -328 … 2192°F 0.1°C / 0.18°F ± 0.3°C / 0.54°F
K -200 … 1372°C /  0.1°C / 0.18°F ± 0.3°C / 0.54°F
T -200 … 400°C /    -328 … 752°F 0.1°C / 0.18°F ± 0.3°C / 0.54°F
B 450 … 1800°C /     842 … 3272°F 0.1°C / 0.18°F ± 0.5°C / 0.9°F
R 0 … 1750°C /           32 … 3182°F 0.1°C / 0.18°F ± 0.5°C / 0.9°F
S 0 … 1750°C /           32 … 3182°F 0.1°C / 0.18°F ± 0.5°C / 0.9°F
N -200 … 1300°C /   -328 … 2372°F 0.1°C / 0.18°F ± 0.3°C / 0.54°F
mV -10 … 80 mV

-10 … 250 mV
0.001 mV

0.01 mV
± 0.02% of v. Mw. ± 4 μm

± 0.02% of v.
Mw. ± 0.02 mV
       
Technical data Frequency measurement  
   
Measuring range Resolution
0.0143 … 9.9999 Hz 0.0001 Hz
10 … 99,999 Hz 0.001 Hz
100 … 999.99 Hz 0.01
1000 … 9999.9 Hz 0.1 Hz
10000 … 50,000 Hz 1 Hz
   
Function Specification
   
Triggering threshold 0 … 12V in 1V increments
Measurement accuracy ± 0.01% of v. Mw. ± 1 Dgt
Supported units Hz, kHz, cph, cpm, sec., Msec., Μsec
   
Technical data Pulse counting  
   
Function Specification
   
Measuring range 0 … 999999 pulses
Triggering threshold 0 … 12V in 1V increments
   
Technical data Frequency generation  
   
Measuring range Resolution
   
0.0005 … 0.5 Hz 0.00001 Hz
0.5 … 50 Hz 0.0001 Hz
50 … 500 Hz 0.001 Hz
500 … 5000 Hz 0.01 Hz
5000 … 10000 Hz 0.1 Hz
   
Function Specification
   
Output amplitude positive square wave 0 … 12V PP (± 0.5V)
Output amplitude symmetrical square wave 0 … 6V PP (± 0.5V)
Measurement accuracy ± 0.02% of reading ± 2
Duty cycle 1 … 99% (up to 500 Hz)
Supported units Hz, KHz, cph, cpm, sec., Msec., Μsec.
   
Technical data Pulse generation  
   
Function Specification
   
Measuring range 0 … 999999 pulses
Resolution 1 pulse
Output amplitude positive square wave 0 … 12V PP (± 0.5V PP)
Output amplitude symmetrical square wave 0 … 6V PP (± 0.5V PP)
Pulse frequency 0.0005 … 10000 Hz
Duty cycle 1 … 99% (up to 500 Hz)

Delivery Scope

1 x Process Calibrator / Simulator PCE-MCA 50
6 x Measuring cable (red / black)
6 x Crocodile clip (red / black)
1 x USB cable
1 x Charging adapter
1 x Test lead Cu-Cu (thermocouple connection)
1 x Carrying bag
1 x Instruction manual



Downloads