Current Clamp PCE-CM 5

Views: 1103

$0.00

SKU: ba51bf74b1b8 Category:

Description

Current clamp PCE-CM 5
Digital multimeter with NCV measurement / Current measurement up to 200 A AC /
Frequency measurement directly at the current clamp / Ready for immediate use / Simple operation


The digital multimeter is a multimeter with a multitude of different functions. Thus, with the digital multimeter, current measurements up to 200 A AC can be carried out without contact. This current range of the digital multimeter already covers a large range of current measurements. Thanks to the contactless current measurements of the digital multimeter can be measured during operation. Thus, no measurement preparation must be made with the digital multimeter, since it is possible to measure directly on the line to be measured.

Another contactless feature of the digital multimeter is the NCV (Not Connected Voltage) measurement. In this measurement, the digital multimeter can indicate whether a voltage is applied to a line. Again, no measurement preparation must be carried out during operation with the digital multimeter. These two features of the digital multimeter reduce the risk of injury from electric shock.

Other useful functions of the ammeter are the measurement of the resistance and the continuity test. With the continuity check of the digital multimeter, it can be determined, for example, whether a relay in a switch box is completely closed. Thanks to the fast measuring frequency of the digital multimeter, possible power fluctuations can be determined. This makes the digital multimeter an indispensable tool for every electrician.

– Inductive current measurement up to 200 A AC
– Voltage measurement with frequency meter
– “Hold” function for freezing the measured value
– Temperature measurement with thermocouple
– Small and compact design
– Smaller internal resistance with the LowZ function


Specification

Alternating current  
Measuring range Resolution Accuracy
200 A 0.1 A ± (3.0% + 3 digits)
Frequency range: 40 … 400 Hz
Maximum input current: 200 A AC
   
 
Direct current  
Measuring range Resolution Accuracy
600 µA 0.1 µA ± (1.0% + 4 digits)
1000 µA 1 µA ± (1.0% + 4 digits)
Maximum input current: 1000 µA
   
 
DC  
Measuring range Resolution Accuracy
600 mV 0.1 mV ± (0.7% + 3 digits)
6V 0.001 V ± (0.7% + 3 digits)
60V 0.01 V ± (0.7% + 3 digits)
600V 0.1 V ± (0.7% + 3 digits)
Input impedance: 10 MΩ
maximum input voltage: 600V DC AC rms
     
 
AC  
Measuring range Resolution Accuracy
6V 0.001V ± (0.8% + 3 digits)
60V 0.01V ± (0.8% + 3 digits)
600V 0.1V ± (0.8% + 3 digits)
Input impedance: 10 MΩ
Maximum input voltage: 600V DC AC rms
Frequency range: 40 … 400 Hz
 
 
LowZ AC / DC  
Measuring range Resolution    Accuracy
600V 0.1V ± (2.0% + 3 digits)
Input impedance: 10 MΩ
Maximum input voltage: 600V DC AC rmsS
Frequency range: 40 … 400 Hz
     
 
Resistance  
Measuring range Resolution Accuracy
600 Ω 0.1 Ω ± (0.8% + 3 digits)
6 kΩ 0.001 kΩ ± (0.8% + 3 digits)
60 kΩ 0.01 kΩ ± (0.8% + 3 digits)
600 kΩ 0.1 kΩ ± (0.8% + 3 digits)
6 MΩ 0.001 MΩ ± (1.2% + 3 digits)
60 MΩ 0.1 MΩ ± (1.2% + 3 digits)
Test voltage (open circuit): 0.4V
Surge protection: 250V AC / DC rms
 
 
Continuity test  
Measuring range Resolution accuracy
0.1 Ω
Surge protection: 250 V AC / DC rms
Beep at <50 Ω
     
 
Diode test  
Measuring range Resolution Accuracy
0.001V
Surge protection: 250V AC / DC rms
Forward current: 1-mA DC
Forward voltage: 3.3V DC
     
 
Capacities  
Measuring range Resolution Accuracy
99.99 nF 0.01 nF ± (4.0% + 5 digits)
999.9 nF 0.1 nF ± (4.0% + 5 digits)
9.999 µF 0.001 µF ± (4.0% + 5 digits)
99.99 µF 0.01 µF ± (4.0% + 5 digits)
999.9 µF 0.1 µF ± (4.0% + 5 digits)
9.999 mF 1 µF ± (4.0% + 5 digits)
99.99 mF 0.01 mF ± (4.0% + 5 digits)
Surge protection: 250V AC / DC rms
     
 
Temperature (thermocouple type K)  
Measuring range Resolution Accuracy
-20 … 0°C 1°C ± (3.0% + 2 digits)
1 … 400°C 1°C ± (2.0% + 2 digits)
-4 … 32°F 1°F ± (3.0% + 4 digits)
33 … 752°F 1°F ± (2.0% + 4 digits)
Surge protection: 250V AC / DC rms
     
 
Frequency (with current probe)  
Measuring range Resolution Accuracy
99.99 Hz 0.01 Hz ± (1.5% + 5 digits)
999.9 Hz 0.1 Hz ± (1.5% + 5 digits)
> 1 kHz 0.001 kHz for reference only
Frequency range: 10 Hz … 1 kHz
Maximum input current: 200 A AC rms
Input range: > 60 A AC rms (if the input current increases, the frequency also increases)
     
 
Frequency (when measuring voltage)  
Measuring range Resolution Accuracy
99.99 Hz 0.01 Hz ± (1.5% + 5 digits)
999.9 Hz 0.1 Hz ± (1.5% + 5 digits)
9.999 Hz 0.001 kHz ± (1.5% + 5 digits)
> 10 kHz 0.01 kHz for reference only
Frequency range: 10 Hz … 10 kHz
     
 
Frequency (direct measurement)  
Measuring range Resolution Accuracy
99.99 Hz 0.01 Hz ± (0.3% + 5 digits)
999.9 Hz 0.1 Hz ± (0.3% + 5 digits)
9.999 Hz 1 Hz ± (0.3% + 5 digits)
99.99 kHz 0.01 kHz ± (0.3% + 5 digits)
999.9 kHz 0.1 kHz ± (0.3% + 5 digits)
9.999 kHz 1 kHz ± (0.3% + 5 digits)
99.99 MHz 0.01 MHz ± (0.3% + 5 digits)

Delivery Scope

1 x Current clamp PCE-CM 5
1 x pair of test leads
1 x transport bag 
1 x 9V Bockbatterie
1 x user manual





Downloads